Browse by UCL Departments and Centres
Group by: Author | Type
Number of items: 13.
A
Alekseeva, T.;
(2012)
Introducing controllable 3D features into dense collagen
constructs for tissue engineering applications.
Doctoral thesis , UCL (University College London).
|
D
de Jager, K;
(2012)
Knee extension with less hip flexion: biomechanical and evoked EMG analysis during selective surface stimulation of the quadriceps.
Doctoral thesis , UCL (University College London).
|
G
García Gareta, E.;
(2012)
Development of a bone tissue-engineered construct to enhance new bone formation in revision total hip replacement.
Doctoral thesis , UCL (University College London).
|
Goode, AE;
Perkins, JM;
Sandison, A;
Karunakaran, C;
Cheng, H;
Wall, D;
Skinner, JA;
... Ryan, MP; + view all
(2012)
Chemical speciation of nanoparticles surrounding metal-on-metal hips.
Chem Commun (Camb)
, 48
(67)
8335 - 8337.
10.1039/c2cc33016d.
|
Grange, S;
Qi, L;
Frank, C;
Ferguson-Pell, M;
Smitham, P;
Holloway, C;
Taylor, S;
... Tyler, N; + view all
(2012)
Establishing Translational Research Pipelines for Smart Devices.
In:
(Proceedings) IFESS 2012.
IFESS
|
H
Hart, AJ;
Matthies, A;
Henckel, J;
Ilo, K;
Skinner, J;
Noble, PC;
(2012)
Understanding why metal-on-metal hip arthroplasties fail: a comparison between patients with well-functioning and revised birmingham hip resurfacing arthroplasties. AAOS exhibit selection.
J Bone Joint Surg Am
, 94
(4)
, Article e22. 10.2106/JBJS.K.01266.
|
Hart, AJ;
Satchithananda, K;
Liddle, AD;
Sabah, SA;
McRobbie, D;
Henckel, J;
Cobb, JP;
... Mitchell, AW; + view all
(2012)
Pseudotumors in association with well-functioning metal-on-metal hip prostheses: a case-control study using three-dimensional computed tomography and magnetic resonance imaging.
J Bone Joint Surg Am
, 94
(4)
317 - 325.
10.2106/JBJS.J.01508.
|
N
Nonclercq, A;
Lonys, L;
Vanhoestenberghe, A;
Demosthenous, A;
Donaldson, N;
(2012)
Safety of multi-channel stimulation implants: a single blocking capacitor per channel is not sufficient after single-fault failure.
Medical & Biological Engineering & Computing
, 50
(4)
pp. 403-410.
10.1007/s11517-012-0889-5.
|
P
Powell, J;
Papadaki, A;
Hand, J;
Hart, A;
McRobbie, D;
(2012)
Numerical simulation of SAR induced around Co-Cr-Mo hip prostheses in situ exposed to RF fields associated with 1.5 and 3 T MRI body coils.
Magn Reson Med
, 68
(3)
960 - 968.
10.1002/mrm.23304.
|
S
Sampson, B;
Hart, A;
(2012)
Clinical usefulness of blood metal measurements to assess the failure of metal-on-metal hip implants.
Ann Clin Biochem
, 49
(Pt 2)
118 - 131.
10.1258/acb.2011.011141.
|
T
Taylor, SJG;
(2012)
Orthopaedic telemetry: inductive coupling.
Presented at: Body Sensor Networks implantables workshop, London, UK.
|
Taylor, SJG;
(2012)
Orthopaedic telemetry: the clinical needs and some implant designs.
Presented at: Body Sensor Networks implantables workshop, London, UK.
|
U
Underwood, RJ;
Zografos, A;
Sayles, RS;
Hart, A;
Cann, P;
(2012)
Edge loading in metal-on-metal hips: low clearance is a new risk factor.
Proc Inst Mech Eng H
, 226
(3)
217 - 226.
10.1177/0954411911431397.
|