Zhang, H;
Ma, X;
You, S;
Wang, Y;
Zheng, X;
Ye, T;
Zheng, W;
(2018)
Mathematical modeling and performance analysis of a solar air collector with slit-perforated corrugated plate.
Solar Energy
, 167
pp. 147-157.
10.1016/j.solener.2018.04.003.
Preview |
Text
Wei_Revised Manuscript with NO Changes Marked.pdf - Accepted Version Download (2MB) | Preview |
Abstract
In this paper, a solar air collector with slit-perforated corrugated plate is put forward, which is a combination of transpired solar air collector and corrugated packing solar air collector. The slit-perforated corrugated plate can enlarge the heat collection area and reinforce the jet impingement largely. The mathematical model is developed to predict thermal performance of the collector. Simulation results of temperature distribution in the collector are verified by the experimental data with the average bias of 4.8%. The local resistance coefficient of the collector is obtained though experimental results. The effects of key parameters on thermal efficiency are analyzed. It can be found that the height of absorber plate has the largest effect on thermal performance among structure parameters. And when air velocity in the collector increases to 1.14 m/s, effective efficiency can reach the peak, 67.83%. Compared with other transpired solar air collectors, the present solar air collector has better thermal performance and lower resistance. Case study shows that the application of the present solar air collector can produce 820.7 MJ in the heating season, which can save 43.1 kg standard coal and reduce 102.1 kg carbon dioxide emission. Hence, there is application potential for space heating in the cold region.
Type: | Article |
---|---|
Title: | Mathematical modeling and performance analysis of a solar air collector with slit-perforated corrugated plate |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1016/j.solener.2018.04.003 |
Publisher version: | http://doi.org/10.1016/j.solener.2018.04.003 |
Language: | English |
Additional information: | © 2018 Elsevier Ltd. All rights reserved. This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions. |
Keywords: | Glazed transpired solar air collector; Slit-perforated corrugated plate; Local resistance coefficient; Performance analysis |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of the Built Environment |
URI: | https://discovery-pp.ucl.ac.uk/id/eprint/10046510 |
Archive Staff Only
![]() |
View Item |