UCL Discovery Stage
UCL home » Library Services » Electronic resources » UCL Discovery Stage

Torso shape detection to improve lung monitoring

De Gelidi, S; Seifnaraghi, N; Bardill, A; Tizzard, A; Wu, Y; Sorantin, E; Nordebo, S; ... Bayford, RH; + view all (2018) Torso shape detection to improve lung monitoring. Physiological Measurement , 39 (7) , Article 074001. 10.1088/1361-6579/aacc1c. Green open access

[thumbnail of shape_abs.pdf]
Preview
Text
shape_abs.pdf - Accepted Version

Download (8MB) | Preview

Abstract

Newborns with lung immaturity often require continuous monitoring and treatment of their lung ventilation in intensive care units, especially if born preterm. Recent studies indicate that Electrical Impedance Tomography (EIT) is feasible in newborn
 infants and children, and can quantitatively identify changes in regional lung aeration and ventilation following alterations to respiratory conditions. Information on the patient-specic shape of the torso and its role in minimizing the artefacts in the
 reconstructed images can improve the accuracy of the clinical parameters obtained from EIT. Currently, only idealized models or those segmented from CT scans are usually adopted. This study presents and compares two methodologies that can
 detect the patient-specic torso shape by means of wearable devices based on: (1) previously reported bend sensor technology and (2) a novel approach based on the use of accelerometers. The reconstruction of different phantoms, taking into account
 anatomical asymmetries and different sizes, are produced for comparison. As a result, the accelerometers are more versatile than bend sensors, which cannot be used on bigger cross-sections. The computational study estimates the optimal number of
 accelerometers required in order to generate an image reconstruction comparable to the use of a CT scan as the forward model. Furthermore, since the patient position is crucial to monitoring lung ventilation, the orientation of the phantoms is automatically
 detected by the accelerometer-based method.

Type: Article
Title: Torso shape detection to improve lung monitoring
Location: England
Open access status: An open access version is available from UCL Discovery
DOI: 10.1088/1361-6579/aacc1c
Publisher version: https://doi.org/10.1088/1361-6579/aacc1c
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Accelerometers, EIT, Orientation, Reconstruction, Shape detection
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Electronic and Electrical Eng
URI: https://discovery-pp.ucl.ac.uk/id/eprint/10051118
Downloads since deposit
6,992Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item