Greig, AR;
Suárez de la Fuente, S;
Bucknall, R;
Pawling, R;
Larsen, U;
Kerdan, IG;
(2018)
Using the forward movement of a container ship navigating in the Arctic to air-cool a marine organic Rankine cycle unit.
Energy
, 159
pp. 1046-1059.
10.1016/j.energy.2018.06.143.
Preview |
Text
Greig Final version submitted after reviewers comments.pdf - Accepted Version Download (1MB) | Preview |
Abstract
Ice coverage in the Arctic is declining, opening up new shipping routes which can drastically reduce voyage lengths between Asia and Europe. There is also a drive to improve ships energy efficiency to meet international emissions design regulations such as the mandated Energy Efficiency Design Index. The organic Rankine cycle is one thermodynamic cycle that is being actively examined to improve the design and operational efficiency of ships. Low heat sink temperatures can significantly increase waste heat recovery systems thermal efficiency. In Arctic regions, the ambient air temperature can be much lower than the sea temperature, presenting interesting opportunities. However, using air as the cooling medium requires larger condensers and power compared to a water-cooled system. This paper investigates the exploitation of the forward movement of a container ship navigating in the Arctic and density-change induced flows as means of moving air through the condenser to reduce the fan power required. The organic Rankine cycle unit uses the waste heat available from the scavenge air to produce electric power. A two-step optimisation method is used with the objective of minimising the annual CO2 emissions of the ship. The results suggest that the supportive cooling could reduce the fan power by up to 60%, depending on ambient air temperature.
Type: | Article |
---|---|
Title: | Using the forward movement of a container ship navigating in the Arctic to air-cool a marine organic Rankine cycle unit |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1016/j.energy.2018.06.143 |
Publisher version: | https://doi.org/10.1016/j.energy.2018.06.143 |
Language: | English |
Additional information: | This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions. |
Keywords: | Shipping, Arctic, Efficiency, CO2 emission reductions, Air-cooling, Waste heat recovery systems, organic Rankine cycle |
UCL classification: | UCL UCL > Provost and Vice Provost Offices UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Mechanical Engineering UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of the Built Environment UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of the Built Environment > Bartlett School Env, Energy and Resources |