UCL Discovery Stage
UCL home » Library Services » Electronic resources » UCL Discovery Stage

Optimal repetition time reduction for single subject event-related functional magnetic resonance imaging

McDowell, AR; Carmichael, DW; (2018) Optimal repetition time reduction for single subject event-related functional magnetic resonance imaging. Magnetic Resonance in Medicine 10.1002/mrm.27498. Green open access

[thumbnail of McDowell_et_al-2018-Magnetic_Resonance_in_Medicine.pdf]
Preview
Text
McDowell_et_al-2018-Magnetic_Resonance_in_Medicine.pdf - Published Version

Download (582kB) | Preview

Abstract

PURPOSE: Short TRs are increasingly used for fMRI as fast sequences such as simultaneous multislice excitation become available. These have been associated with apparent sensitivity improvements, although greater temporal autocorrelation at shorter TRs can inflate sensitivity measurements leading to uncertainty regarding the optimal approach. METHODS: In volunteers (n = 10), the optimal TR was assessed at the single subject level for event-related designs (visual stimulation) with 4 frequencies of presentation at 4 TR values (412-2550 ms). T-values in the visual cortex localized in each individual were obtained and receiver operating characteristics (ROC) analysis was performed by counting voxels within and outside expected task active regions at different thresholds. This analysis was repeated using 4 different autoregressive (AR) models; SPM AR(1) and SPM AR(fast) which globally estimate autocorrelation, and fMRIstat AR(1) and AR(5) that use a local estimate. RESULTS: The use of modest multiband factors of 2 or 3 with a reduction in TR to 1000 ± 200 ms had greater sensitivity and specificity as shown by higher T-values in visual cortex and ROC analysis. At these TRs, the ROC analysis demonstrated that a local AR model fit improved performance while high order AR models were unnecessary. CONCLUSIONS: Modest TR reductions (to 1000 ± 200 ms) optimally improved event-related fMRI performance independent of design frequency. Autoregressive models with a local as opposed to global fit performed better, while low order autoregressive models were sufficient at the optimal TR.

Type: Article
Title: Optimal repetition time reduction for single subject event-related functional magnetic resonance imaging
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1002/mrm.27498
Publisher version: https://doi.org/10.1002/mrm.27498
Language: English
Additional information: This is an open access article under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Keywords: EEG-fMRI, autoregressive model, event related, fMRI, multiband, simultaneous multislice
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology > Brain Repair and Rehabilitation
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > UCL GOS Institute of Child Health
URI: https://discovery-pp.ucl.ac.uk/id/eprint/10062523
Downloads since deposit
6,992Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item