Fallatah, SM;
Pizzini, FB;
Gomez-Anson, B;
Magerkurth, J;
De Vita, E;
Bisdas, S;
Jäger, HR;
... Golay, X; + view all
(2018)
A visual quality control scale for clinical arterial spin labeling images.
European Radiology Experimental
, 2
, Article 45. 10.1186/s41747-018-0073-2.
Preview |
Text
A visual quality control scale for clinical arterial spin labeling images.pdf - Published Version Download (1MB) | Preview |
Abstract
BACKGROUND: Image-quality assessment is a fundamental step before clinical evaluation of magnetic resonance images. The aim of this study was to introduce a visual scoring system that provides a quality control standard for arterial spin labeling (ASL) and that can be applied to cerebral blood flow (CBF) maps, as well as to ancillary ASL images. METHODS: The proposed image quality control (QC) system had two components: (1) contrast-based QC (cQC), describing the visual contrast between anatomical structures; and (2) artifact-based QC (aQC), evaluating image quality of the CBF map for the presence of common types of artifacts. Three raters evaluated cQC and aQC for 158 quantitative signal targeting with alternating radiofrequency labelling of arterial regions (QUASAR) ASL scans (CBF, T1 relaxation rate, arterial blood volume, and arterial transient time). Spearman correlation coefficient (r), intraclass correlation coefficients (ICC), and receiver operating characteristic analysis were used. RESULTS: Intra/inter-rater agreement ranged from moderate to excellent; inter-rater ICC was 0.72 for cQC, 0.60 for aQC, and 0.74 for the combined QC (cQC + aQC). Intra-rater ICC was 0.90 for cQC; 0.80 for aQC, and 0.90 for the combined QC. Strong correlations were found between aQC and CBF maps quality (r = 0.75), and between aQC and cQC (r = 0.70). A QC score of 18 was optimal to discriminate between high and low quality clinical scans. CONCLUSIONS: The proposed QC system provided high reproducibility and a reliable threshold for discarding low quality scans. Future research should compare this visual QC system with an automatic QC system.
Type: | Article |
---|---|
Title: | A visual quality control scale for clinical arterial spin labeling images |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1186/s41747-018-0073-2 |
Publisher version: | https://doi.org/10.1186/s41747-018-0073-2 |
Language: | English |
Additional information: | Copyright © The Author(s). 2018 Open Access. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
Keywords: | Arterial spin labelling, Magnetic resonance imaging, Perfusion imaging, Quality control |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > Div of Psychology and Lang Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology > Brain Repair and Rehabilitation |
URI: | https://discovery-pp.ucl.ac.uk/id/eprint/10066503 |
Archive Staff Only
View Item |