Validation of the Kinetik Blood Pressure Monitor-Series 1 for use in adults at home and in clinical settings, according to the 2002 European Society of Hypertension International Protocol on the validation of blood pressure devices

Schwartz, CL; Edwards, K; Gamble, W; Kirkham, A; Lacy, P; Lewis, P; McDonagh, STJ; ... Williams, B; + view all (2020) Validation of the Kinetik Blood Pressure Monitor-Series 1 for use in adults at home and in clinical settings, according to the 2002 European Society of Hypertension International Protocol on the validation of blood pressure devices. Journal of Human Hypertension 10.1038/s41371-020-00445-9. (In press). Green open access

[thumbnail of 11694_2_merged_1603897011.pdf]
Preview
Text
11694_2_merged_1603897011.pdf - Accepted Version

Download (452kB) | Preview

Abstract

The aim of this study was to assess the blood pressure (BP) measurement accuracy of the Kinetik Blood Pressure Monitor—Series 1 (BPM-1) for use in home or clinical settings according to the 2002 European Society of Hypertension International Protocol (ESH-IP). Forty-two participants were recruited to fulfil the required number of systolic and diastolic BP measurements according to the ESH-IP. Nine sequential same-arm BP readings were measured and analysed for each participant using the test device and observer mercury standard readings according to the 2002 ESH-IP. Forty one participants were used to obtain 33 sets of systolic and diastolic BP readings and were included in the analysis. Mean difference between the device measurements and the observer (mercury standard) measurements was 1.1 ± 7.2/1.1 ± 6.8 mmHg (mean ± standard deviation; systolic/diastolic). The number of systolic BP differences between the test and observer measurements that fell within 5, 10 and 15 mmHg was 65, 86 and 92. For diastolic readings, the number of test—observer measurement differences within 5, 10 and 15 mmHg was 77, 91 and 94. The number of participants with at least two out of three differences within 5 mmHg was 28 for systolic and 40 for diastolic BP readings. Three participants had no differences between the test and observer measurements within 5 mmHg in both the systolic and diastolic measurement categories. The Kinetik BPM-1 device fulfilled the requirements of the ESH-IP validation procedure and can be recommended for clinical use and self-measurement within the home.

Type: Article
Title: Validation of the Kinetik Blood Pressure Monitor-Series 1 for use in adults at home and in clinical settings, according to the 2002 European Society of Hypertension International Protocol on the validation of blood pressure devices
Open access status: An open access version is available from UCL Discovery
DOI: 10.1038/s41371-020-00445-9
Publisher version: https://doi.org/10.1038/s41371-020-00445-9
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Science & Technology, Life Sciences & Biomedicine, Peripheral Vascular Disease, Cardiovascular System & Cardiology
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Population Science and Experimental Medicine
URI: https://discovery-pp.ucl.ac.uk/id/eprint/10121837
Downloads since deposit
1,848Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item