Gomez, A;
Hurtado, M;
Callejas, A;
Torres, J;
Saffari, N;
Rus, G;
(2021)
Experimental Evidence of Generation and Reception by a Transluminal Axisymmetric Shear Wave Elastography Prototype.
Diagnostics
, 11
(4)
, Article 645. 10.3390/diagnostics11040645.
Preview |
Text
Gomez2021a - Experimental evidence of generation and reception by a transluminal axisymmetric SWE prototype.pdf - Published Version Download (12MB) | Preview |
Abstract
Experimental evidence on testing a non-ultrasonic-based probe for a new approach in transluminal elastography was presented. The proposed modality generated shear waves by inducing oscillatory rotation on the lumen wall. Detection of the propagated waves was achieved at a set of receivers in mechanical contact with the lumen wall. The excitation element of the probe was an electromagnetic rotational actuator whilst the sensing element was comprised by a uniform anglewise arrangement of four piezoelectric receivers. The prototype was tested in two soft-tissue-mimicking phantoms that contained lumenlike conduits and stiffer inclusions. The shear wave speed of the different components of the phantoms was characterized using shear wave elastography. These values were used to estimate the time-of-flight of the expected reflections. Ultrafast ultrasound imaging, based on Loupas' algorithm, was used to estimate the displacement field in transversal planes to the lumenlike conduit and to compare against the readouts from the transluminal transmission-reception tests. Experimental observations between ultrafast imaging and the transluminal probe were in good agreement, and reflections due to the stiffer inclusions were detected by the transluminal probe. The obtained experimental evidence provided proof-of-concept for the transluminal elastography probe and encouraged further exploration of clinical applications.
Type: | Article |
---|---|
Title: | Experimental Evidence of Generation and Reception by a Transluminal Axisymmetric Shear Wave Elastography Prototype |
Location: | Switzerland |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.3390/diagnostics11040645 |
Publisher version: | https://doi.org/10.3390/diagnostics11040645 |
Language: | English |
Additional information: | © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
Keywords: | phantoms, prostate, shear wave elastography imaging, transluminal elastography |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Mechanical Engineering |
URI: | https://discovery-pp.ucl.ac.uk/id/eprint/10126214 |
Archive Staff Only