Chappell, MA;
McConnell, FAK;
Golay, X;
Günther, M;
Hernandez-Tamames, JA;
van Osch, MJ;
Asllani, I;
(2021)
Partial Volume Correction in Arterial Spin Labeling Perfusion MRI: A method to disentangle anatomy from physiology or an analysis step too far?
NeuroImage
, 238
, Article 118236. 10.1016/j.neuroimage.2021.118236.
(In press).
Preview |
Text
Golay_Partial volume correction in arterial spin labeling perfusion MRI- A method to disentangle anatomy from physiology or an analysis step too far_VoR.pdf - Published Version Download (1MB) | Preview |
Abstract
The mismatch in the spatial resolution of Arterial Spin Labeling (ASL) MRI perfusion images and the anatomy of functionally distinct tissues in the brain leads to a partial volume effect (PVE), which in turn confounds the estimation of perfusion to a specific tissue of interest such as grey or white matter. This confound occurs because the image voxels contain a mixture of tissues with disparate perfusion properties, leading to estimated perfusion values that reflect primarily the volume proportions of tissues in the voxel rather than the perfusion of any particular tissue of interest within that volume. It is already recognized that PVE influences studies of brain perfusion, and that its effect might be even more evident in studies where changes in perfusion are co-incident with alterations in brain structure, such as studies involving a comparison between an atrophic patient population vs control subjects, or studies comparing subjects over a wide range of ages. However, the application of PVE correction (PVEc) is currently limited and the employed methodologies remain inconsistent. In this article, we outline the influence of PVE in ASL measurements of perfusion, explain the main principles of PVEc, and provide a critique of the current state of the art for the use of such methods. Furthermore, we examine the current use of PVEc in perfusion studies and whether there is evidence to support its wider adoption. We conclude that there is sound theoretical motivation for the use of PVEc alongside conventional, 'uncorrected', images, and encourage such combined reporting. Methods for PVEc are now available within standard neuroimaging toolboxes, which makes our recommendation straightforward to implement. However, there is still more work to be done to establish the value of PVEc as well as the efficacy and robustness of existing PVEc methods.
Type: | Article |
---|---|
Title: | Partial Volume Correction in Arterial Spin Labeling Perfusion MRI: A method to disentangle anatomy from physiology or an analysis step too far? |
Location: | United States |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1016/j.neuroimage.2021.118236 |
Publisher version: | https://doi.org/10.1016/j.neuroimage.2021.118236 |
Language: | English |
Additional information: | © 2021 The Author(s). Published by Elsevier Inc. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/) |
Keywords: | Arterial Spin Labeling, Cerebral Blood Flow, MRI, Partial Volume Effect, Perfusion, aging and dementia, atrophy, fMRI |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology > Brain Repair and Rehabilitation |
URI: | https://discovery-pp.ucl.ac.uk/id/eprint/10129678 |
Archive Staff Only
View Item |