UCL Discovery Stage
UCL home » Library Services » Electronic resources » UCL Discovery Stage

The Optimization of Ti Gradient Porous Structure Involves the Finite Element Simulation Analysis

Liu, B; Xu, W; Lu, X; Tamaddon, M; Chen, M; Dong, J; Liu, Y; ... Liu, C; + view all (2021) The Optimization of Ti Gradient Porous Structure Involves the Finite Element Simulation Analysis. Frontiers in Materials , 8 , Article 642135. 10.3389/fmats.2021.642135. Green open access

[thumbnail of Liu_fmats-08-642135.pdf]
Preview
Text
Liu_fmats-08-642135.pdf - Published Version

Download (2MB) | Preview

Abstract

Titanium (Ti) and its alloys are attracting special attention in the field of dentistry and orthopedic bioengineering because of their mechanical adaptability and biological compatibility with the natural bone. The dental implant is subjected to masticatory forces in the oral environment and transfers these forces to the surrounding bone tissue. Therefore, by simulating the mechanical behavior of implants and surrounding bone tissue we can assess the effects of implants on bone growth quite accurately. In this study, dental implants with different gradient pore structures that consisted of simple cubic (structure a), body centered cubic (structure b) and side centered cubic (structure c) were designed, respectively. The strength of the designed gradient porous implant in the oral environment was simulated by three-dimensional finite element simulation technique to assess the mechanical adaptation by the stress-strain distribution within the surrounding bone tissue and by examining the fretting of the implant-bone interface. The results show that the maximum equivalent stress and strain in the surrounding bone tissue increase with the increase of porosity. The stress distribution of the gradient implant with a smaller difference between outer and inner pore structure is more uniform. So, a-b type porous implant exhibited less stress concentration. For a-b structure, when the porosity is between 40 and 47%, the stress and strain of bone tissue are in the range of normal growth. When subject to lingual and buccal stresses, an implant with higher porosity can achieve more uniform stress distribution in the surrounding cancellous bone than that of low porosity implant. Based on the simulated results, to achieve an improved mechanical fixation of the implant, the optimum gradient porous structure parameters should be: average porosity 46% with an inner porosity of 13% (b structure) and outer porosity of 59% (a structure), and outer pore sized 500 μm. With this optimized structure, the bone can achieve optimal ingrowth into the gradient porous structure, thus provide stable mechanical fixation of the implant. The maximum equivalent stress achieved 99 MPa, which is far below the simulation yield strength of 299 MPa.

Type: Article
Title: The Optimization of Ti Gradient Porous Structure Involves the Finite Element Simulation Analysis
Open access status: An open access version is available from UCL Discovery
DOI: 10.3389/fmats.2021.642135
Publisher version: http://dx.doi.org/10.3389/fmats.2021.642135
Language: English
Additional information: © 2021 Liu, Xu, Lu, Tamaddon, Chen, Dong, Liu, Guo, Zhang, Qu, He and Liu. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
Keywords: titanium, gradient porosity, oral implants, three-dimensional finite element simulation, bone stress, BONE INGROWTH, MECHANICAL-PROPERTIES, TITANIUM, BIOMATERIALS, IMPLANTS, ALLOYS
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci > Department of Ortho and MSK Science
URI: https://discovery-pp.ucl.ac.uk/id/eprint/10129930
Downloads since deposit
7,752Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item