The effects of manual airing strategies and architectural factors on the indoor air quality in college classrooms: a case study.
Air Quality, Atmosphere & Health
, 15
pp. 1-13.
10.1007/s11869-021-01074-y.
Preview |
Text
Wei_The effects of manual airing strategies and architectural factors on the indoor air quality in college classrooms- a case study_AAM.pdf - Accepted Version Download (1MB) | Preview |
Abstract
In China, natural ventilation is a common way of improving indoor air quality (IAQ) in college classrooms. However, until now, the effects of both manual airing strategies and architectural factors on IAQ in classrooms have not been well explored. The present work aimed to investigate the effect of manual airing strategies, such as opening doors and opening exterior or interior windows, on the concentrations of both carbon dioxide (CO_{2}) and fine particulate matter (PM_{2.5}) in classrooms using field measurements. Through simulation, the effects of floor level, room orientation and the height of interior windows on CO_{2} concentration were also analysed. The results of this study revealed that (1) simultaneously opening doors and exterior windows or opening the doors alone could effectively reduce the indoor CO2 concentration, but the same effect could not be achieved by opening interior windows only; (2) the indoor PM_{2.5} concentration was primarily affected by the level of outdoor PM_{2.5}, and it may exceed the recommended limit by 33% when the outdoor pollution level is high, even with closed doors and windows; and (3) in winter, both floor level and classroom orientation exerted a significant influence on the indoor CO_{2} concentration, but the height of interior windows had no effect.
Type: | Article |
---|---|
Title: | The effects of manual airing strategies and architectural factors on the indoor air quality in college classrooms: a case study |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1007/s11869-021-01074-y |
Publisher version: | https://doi.org/10.1007/s11869-021-01074-y |
Language: | English |
Additional information: | This version is the author accepted manuscript. For information on re-use, please refer to the publisher's terms and conditions. |
Keywords: | Indoor air quality, Classrooms, Manual airing strategies, Natural ventilation, Influential factors |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of the Built Environment |
URI: | https://discovery-pp.ucl.ac.uk/id/eprint/10133710 |
Archive Staff Only
![]() |
View Item |