Fanni, BM; Sauvage, E; Celi, S; Norman, W; Vignali, E; Landini, L; Schievano, S; ... Capelli, C; + view all (2020) A Proof of Concept of a Non-Invasive Image-Based Material Characterization Method for Enhanced Patient-Specific Computational Modeling. Cardiovascular Engineering and Technology , 11 (5) pp. 532-543. 10.1007/s13239-020-00479-7. Green open access

[thumbnail of FanniB_CVET2020.pdf]
Preview
Text
FanniB_CVET2020.pdf - Accepted Version

Download (724kB) | Preview

Abstract

PURPOSE: Computational models of cardiovascular structures rely on their accurate mechanical characterization. A validated method able to infer the material properties of patient-specific large vessels is currently lacking. The aim of the present study is to present a technique starting from the flow-area (QA) method to retrieve basic material properties from magnetic resonance (MR) imaging. METHODS: The proposed method was developed and tested, first, in silico and then in vitro. In silico, fluid-structure interaction (FSI) simulations of flow within a deformable pipe were run with varying elastic modules (E) between 0.5 and 32 MPa. The proposed QA-based formulation was assessed and modified based on the FSI results to retrieve E values. In vitro, a compliant phantom connected to a mock circulatory system was tested within MR scanning. Images of the phantom were acquired and post-processed according to the modified formulation to infer E of the phantom. Results of in vitro imaging assessment were verified against standard tensile test. RESULTS: In silico results from FSI simulations were used to derive the correction factor to the original formulation based on the geometrical and material characteristics. In vitro, the modified QA-based equation estimated an average E = 0.51 MPa, 2% different from the E derived from tensile tests (i.e. E = 0.50 MPa). CONCLUSION: This study presented promising results of an indirect and non-invasive method to establish elastic properties from solely MR images data, suggesting a potential image-based mechanical characterization of large blood vessels.

Type: Article
Title: A Proof of Concept of a Non-Invasive Image-Based Material Characterization Method for Enhanced Patient-Specific Computational Modeling
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1007/s13239-020-00479-7
Publisher version: https://doi.org/10.1007/s13239-020-00479-7
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: 3D printing, FSI, Material properties assessment, Mock circulation loop, PC MRI, QA method
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Childrens Cardiovascular Disease
URI: https://discovery-pp.ucl.ac.uk/id/eprint/10159295
Downloads since deposit
3,800Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item