UCL Discovery Stage
UCL home » Library Services » Electronic resources » UCL Discovery Stage

HbA1c performs well in monitoring glucose control even in populations with high prevalence of medical conditions that may alter its reliability: the OPTIMAL observational multicenter study

Niwaha, Anxious J; Rodgers, Lauren R; Greiner, Rosamund; Balungi, Priscilla A; Mwebaze, Raymond; McDonald, Timothy J; Hattersley, Andrew T; ... Jones, Angus G; + view all (2021) HbA1c performs well in monitoring glucose control even in populations with high prevalence of medical conditions that may alter its reliability: the OPTIMAL observational multicenter study. BMJ Open Diabetes Research & Care , 9 (1) , Article 002350. 10.1136/bmjdrc-2021-002350. Green open access

[thumbnail of Niwaha et al 2021 - HbA1c - BMJ ODRC.pdf]
Preview
Text
Niwaha et al 2021 - HbA1c - BMJ ODRC.pdf - Published Version

Download (977kB) | Preview

Abstract

INTRODUCTION: The utility of HbA1c (glycosylated hemoglobin) to estimate glycemic control in populations of African and other low-resource countries has been questioned because of high prevalence of other medical conditions that may affect its reliability. Using continuous glucose monitoring (CGM), we aimed to determine the comparative performance of HbA1c, fasting plasma glucose (FPG) (within 5 hours of a meal) and random non-fasting glucose (RPG) in assessing glycemic burden. RESEARCH DESIGN AND METHODS: We assessed the performance of HbA1c, FPG and RPG in comparison to CGM mean glucose in 192 Ugandan participants with type 2 diabetes. Analysis was undertaken in all participants, and in subgroups with and without medical conditions reported to affect HbA1c reliability. We then assessed the performance of FPG and RPG, and optimal thresholds, in comparison to HbA1c in participants without medical conditions thought to alter HbA1c reliability. RESULTS: 32.8% (63/192) of participants had medical conditions that may affect HbA1c reliability: anemia 9.4% (18/192), sickle cell trait and/or hemoglobin C (HbC) 22.4% (43/192), or renal impairment 6.3% (12/192). Despite high prevalence of medical conditions thought to affect HbA1c reliability, HbA1c had the strongest correlation with CGM measured glucose in day-to-day living (0.88, 95% CI 0.84 to 0.91), followed by FPG (0.82, 95% CI 0.76 to 0.86) and RPG (0.76, 95% CI 0.69 to 0.81). Among participants without conditions thought to affect HbA1c reliability, FPG and RPG had a similar diagnostic performance in identifying poor glycemic control defined by a range of HbA1c thresholds. FPG of ≥7.1 mmol/L and RPG of ≥10.5 mmol/L correctly identified 78.2% and 78.8%, respectively, of patients with an HbA1c of ≥7.0%. CONCLUSIONS: HbA1c is the optimal test for monitoring glucose control even in low-income and middle-income countries where medical conditions that may alter its reliability are prevalent; FPG and RPG are valuable alternatives where HbA1c is not available.

Type: Article
Title: HbA1c performs well in monitoring glucose control even in populations with high prevalence of medical conditions that may alter its reliability: the OPTIMAL observational multicenter study
Location: England
Open access status: An open access version is available from UCL Discovery
DOI: 10.1136/bmjdrc-2021-002350
Publisher version: https://doi.org/10.1136/bmjdrc-2021-002350
Language: English
Additional information: © Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY (http://creativecommons.org/licenses/by/4.0/). Published by BMJ.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute for Global Health
URI: https://discovery-pp.ucl.ac.uk/id/eprint/10167761
Downloads since deposit
589Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item