Sullivan, Sean D;
Freemantle, Nick;
Gupta, Rishab A;
Wu, Jasmanda;
Nicholls, Charlie J;
Westerbacka, Jukka;
Bailey, Timothy S;
(2022)
Clinical outcomes in high-hypoglycaemia-risk patients with type 2 diabetes switching to insulin glargine 300 U/mL versus a first-generation basal insulin analogue in the United States: Results from the DELIVER High Risk real-world study.
Endocrinology, Diabetes & Metabolism
, 5
(1)
, Article e00306. 10.1002/edm2.306.
Preview |
Text
EDM2-5-e00306.pdf - Published Version Download (702kB) | Preview |
Abstract
Aims: To compare 12-month clinical effectiveness of insulin glargine 300 units/mL (Gla-300) versus first-generation basal insulin analogues (BIAs) (insulin glargine 100 units/mL [Gla-100] or insulin detemir [IDet]) in patients with type 2 diabetes (T2D) who were at high risk of hypoglycaemia and switched from one BIA to a different one (Gla-300 or Gla-100/IDet) in a real-world setting. // Methods: DELIVER High Risk was a retrospective observational cohort study of 2550 patients with T2D who switched BIA to Gla-300 (Gla-300 switchers) and were propensity score-matched (1:1) to patients who switched to Gla-100 or IDet (Gla-100/IDet switchers). Outcomes were change in glycated haemoglobin A1c (HbA1c), attainment of HbA1c goals (<7% and <8%), and incidence and event rates of hypoglycaemia (all-hypoglycaemia and hypoglycaemia associated with an inpatient/emergency department [ED] contact). // Results: HbA1c reductions were similar following switching to Gla-300 or Gla-100/IDet (−0.51% vs. −0.53%; p = .67), and patients showed similar attainment of HbA1c goals. Patients in both cohorts had comparable all-hypoglycaemia incidence and event rates. However, the Gla-300 switcher cohort had a significantly lower risk of inpatient/ED-associated hypoglycaemia (adjusted odds ratio: 0.73, 95% confidence interval: 0.60–0.89; p = .002) and experienced significantly fewer inpatient/ED-associated hypoglycaemic events (0.21 vs. 0.33 events per patient per year; p < .001). // Conclusion: In patients with T2D at high risk of hypoglycaemia, switching to Gla-300 or Gla-100/IDet achieved similar HbA1c reductions and glycaemic goal attainment, but Gla-300 switchers had a significantly lower risk of hypoglycaemia associated with an inpatient/ED contact during 12 months after switching.
Type: | Article |
---|---|
Title: | Clinical outcomes in high-hypoglycaemia-risk patients with type 2 diabetes switching to insulin glargine 300 U/mL versus a first-generation basal insulin analogue in the United States: Results from the DELIVER High Risk real-world study |
Location: | England |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1002/edm2.306 |
Publisher version: | https://doi.org/10.1002/edm2.306 |
Language: | English |
Additional information: | Copyright © 2021 The Authors. Endocrinology, Diabetes & Metabolism published by John Wiley & Sons Ltd. This is an open access article under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
Keywords: | High risk; hypoglycaemia; Insulin glargine 300 units/mL; real-world study; type 2 diabetes |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Inst of Clinical Trials and Methodology UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Inst of Clinical Trials and Methodology > Comprehensive CTU at UCL |
URI: | https://discovery-pp.ucl.ac.uk/id/eprint/10174065 |
Archive Staff Only
![]() |
View Item |