Hama, S;
Kumar, P;
Tiwari, A;
Wang, Y;
Linden, PS;
(2023)
The underpinning factors affecting the classroom air quality, thermal comfort and ventilation in 30 classrooms of primary schools in London.
Environmental Research
, 236
(Pt 2)
, Article 116863. 10.1016/j.envres.2023.116863.
Preview |
PDF
Wang_The underpinning factors affecting the classroom air quality, thermal comfort and ventilation in 30 classrooms of primary schools in London_VoR.pdf - Published Version Download (12MB) | Preview |
Abstract
The health and academic performance of children are significantly impacted by air quality in classrooms. However, there is a lack of understanding of the relationship between classroom air pollutants and contextual factors such as physical characteristics of the classroom, ventilation and occupancy. We monitored concentrations of particulate matter (PM), CO2 and thermal comfort (relative humidity and temperature) across five schools in London. Results were compared between occupied and unoccupied hours to assess the impact of occupants and their activities, different floor coverings and the locations of the classrooms. In-classroom CO2 concentrations varied between 500 and 1500 ppm during occupancy; average CO2 (955 ± 365 ppm) during occupancy was ∼150% higher than non-occupancy. Average PM10 (23 ± 15 μgm-3), PM2.5 (10 ± 4 μgm-3) and PM1 (6 ± 3 μg m-3) during the occupancy were 230, 125 and 120% higher than non-occupancy. Average RH (29 ± 6%) was below the 40–60% comfort range in all classrooms. Average temperature (24 ± 2 °C) was >23 °C in 60% of classrooms. Reduction in PM10 concentration (50%) by dual ventilation (mechanical + natural) was higher than for PM2.5 (40%) and PM1 (33%) compared with natural ventilation (door + window). PM10 was higher in classrooms with wooden (33 ± 19 μg m-3) and vinyl (25 ± 20 μgm-3) floors compared with carpet (17 ± 12 μgm-3). Air change rate (ACH) and CO2 did not vary appreciably between the different floor levels and types. PM2.5/PM10 was influenced by different occupancy periods; highest value (∼0.87) was during non-occupancy compared with occupancy (∼0.56). Classrooms located on the ground floor had PM2.5/PM10 > 0.5, indicating an outdoor PM2.5 ingress compared with those located on the first and third floors (<0.5). The large-volume (>300 m3) classroom showed ∼33% lower ACH compared with small-volume (100–200 m3). These findings provide guidance for taking appropriate measures to improve classroom air quality.
Type: | Article |
---|---|
Title: | The underpinning factors affecting the classroom air quality, thermal comfort and ventilation in 30 classrooms of primary schools in London |
Location: | Netherlands |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1016/j.envres.2023.116863 |
Publisher version: | https://doi.org/10.1016/j.envres.2023.116863 |
Language: | English |
Additional information: | This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third-party material in this article are included in the Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
Keywords: | CO(2), In-classroom air quality, Particulate matter, Thermal comfort, Ventilation |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of the Built Environment UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of the Built Environment > Bartlett School Env, Energy and Resources |