Jaubert, Olivier;
Montalt-Tordera, Javier;
Knight, Daniel;
Arridge, Simon;
Steeden, Jennifer;
Muthurangu, Vivek;
(2023)
HyperSLICE: HyperBand optimized spiral for low-latency interactive cardiac examination.
Magnetic Resonance in Medicine
10.1002/mrm.29855.
(In press).
Preview |
Text
HyperSLICE HyperBand optimized spiral.pdf - Published Version Download (6MB) | Preview |
Abstract
PURPOSE: Interactive cardiac MRI is used for fast scan planning and MR-guided interventions. However, the requirement for real-time acquisition and near-real-time visualization constrains the achievable spatio-temporal resolution. This study aims to improve interactive imaging resolution through optimization of undersampled spiral sampling and leveraging of deep learning for low-latency reconstruction (deep artifact suppression). METHODS: A variable density spiral trajectory was parametrized and optimized via HyperBand to provide the best candidate trajectory for rapid deep artifact suppression. Training data consisted of 692 breath-held CINEs. The developed interactive sequence was tested in simulations and prospectively in 13 subjects (10 for image evaluation, 2 during catheterization, 1 during exercise). In the prospective study, the optimized framework-HyperSLICE- was compared with conventional Cartesian real-time and breath-hold CINE imaging in terms quantitative and qualitative image metrics. Statistical differences were tested using Friedman chi-squared tests with post hoc Nemenyi test (p < 0.05). RESULTS: In simulations the normalized RMS error, peak SNR, structural similarity, and Laplacian energy were all statistically significantly higher using optimized spiral compared to radial and uniform spiral sampling, particularly after scan plan changes (structural similarity: 0.71 vs. 0.45 and 0.43). Prospectively, HyperSLICE enabled a higher spatial and temporal resolution than conventional Cartesian real-time imaging. The pipeline was demonstrated in patients during catheter pull back, showing sufficiently fast reconstruction for interactive imaging. CONCLUSION: HyperSLICE enables high spatial and temporal resolution interactive imaging. Optimizing the spiral sampling enabled better overall image quality and superior handling of image transitions compared with radial and uniform spiral trajectories.
Type: | Article |
---|---|
Title: | HyperSLICE: HyperBand optimized spiral for low-latency interactive cardiac examination |
Location: | United States |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1002/mrm.29855 |
Publisher version: | https://doi.org/10.1002/mrm.29855 |
Language: | English |
Additional information: | © 2023 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
Keywords: | cardiac MRI, deep learning, image reconstruction, interventional, real-time |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Childrens Cardiovascular Disease |