The ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast-Enhanced challenge

Shalom, ES; Kim, H; van der Heijden, RA; Ahmed, Z; Patel, R; Hormuth, DA; DiCarlo, JC; ... Fathi Kazerooni, A; + view all (2024) The ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast-Enhanced challenge. Magnetic Resonance in Medicine 10.1002/mrm.29909. (In press).

[thumbnail of Parker_cleancopy_Manuscript_Revision2.pdf] Text
Parker_cleancopy_Manuscript_Revision2.pdf - Accepted Version
Access restricted to UCL open access staff until 20 December 2024.

Download (1MB)

Abstract

PURPOSE: (Formula presented.) has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for (Formula presented.) quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging–Dynamic Contrast-Enhanced (OSIPI-DCE) challenge was designed to benchmark methods to better help the efforts to standardize (Formula presented.) measurement. METHODS: A framework was created to evaluate (Formula presented.) values produced by DCE-MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for (Formula presented.) quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' (Formula presented.) values, the applied software, and a standard operating procedure. These were evaluated using the proposed (Formula presented.) score defined with accuracy, repeatability, and reproducibility components. RESULTS: Across the 10 received submissions, the (Formula presented.) score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0–1 = lowest–highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in (Formula presented.) analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility. CONCLUSIONS: This study reports results from the OSIPI-DCE challenge and highlights the high inter-software variability within (Formula presented.) estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real-world clinical setting, many of these tools may perform differently with different benchmarking methodology.

Type: Article
Title: The ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast-Enhanced challenge
Location: United States
DOI: 10.1002/mrm.29909
Publisher version: https://doi.org/10.1002/mrm.29909
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: DCE-MRI, challenge, data analysis, glioblastoma, open-science, perfusion
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Computer Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery-pp.ucl.ac.uk/id/eprint/10186859
Downloads since deposit
76Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item