Blister Score: A Novel, Externally Validated Tool for Predicting Cardiac Implantable Electronic Device Infections, and Its Cost-Utility Implications for Antimicrobial Envelope Use

Maclean, Edd; Mahtani, Karishma; Honarbakhsh, Shohreh; Butcher, Charles; Ahluwalia, Nikhil; Dennis, Adam SC; Creta, Antonio; ... Chow, Anthony; + view all (2024) Blister Score: A Novel, Externally Validated Tool for Predicting Cardiac Implantable Electronic Device Infections, and Its Cost-Utility Implications for Antimicrobial Envelope Use. Circulation: Arrhythmia and Electrophysiology , Article e012446. 10.1161/CIRCEP.123.012446. Green open access

[thumbnail of maclean-et-al-2024-blister-score-a-novel-externally-validated-tool-for-predicting-cardiac-implantable-electronic-device.pdf]
Preview
Text
maclean-et-al-2024-blister-score-a-novel-externally-validated-tool-for-predicting-cardiac-implantable-electronic-device.pdf - Published Version

Download (810kB) | Preview

Abstract

BACKGROUND: Antimicrobial envelopes reduce the incidence of cardiac implantable electronic device infections, but their cost restricts routine use in the United Kingdom. Risk scoring could help to identify which patients would most benefit from this technology. METHODS: A novel risk score (BLISTER) was derived from multivariate analysis of factors associated with cardiac implantable electronic device infection. Diagnostic utility was assessed against the existing PADIT score in both standard and high-risk external validation cohorts, and cost-utility models examined different BLISTER and PADIT score thresholds for TYRX antimicrobial envelope allocation. RESULTS: In a derivation cohort (n=7383), cardiac implantable electronic device infection occurred in 59 individuals within 12 months of a procedure (event rate, 0.8%). In addition to the PADIT score constituents, lead extraction (hazard ratio, 3.3 [95% CI, 1.9-6.1]; P<0.0001), C-reactive protein >50 mg/L (hazard ratio, 3.0 [95% CI, 1.4-6.4]; P=0.005), reintervention within 2 years (hazard ratio, 10.1 [95% CI, 5.6-17.9]; P<0.0001), and top-quartile procedure duration (hazard ratio, 2.6 [95% CI, 1.6-4.1]; P=0.001) were independent predictors of infection. The BLISTER score demonstrated superior discriminative performance versus PADIT in the standard risk (n=2854, event rate: 0.8%, area under the curve, 0.82 versus 0.71; P=0.001) and high-risk validation cohorts (n=1961, event rate: 2.0%, area under the curve, 0.77 versus 0.69; P=0.001), and in all patients (n=12 198, event rate: 1%, area under the curve, 0.8 versus 0.75, P=0.002). In decision-analytic modeling, the optimum scenario assigned antimicrobial envelopes to patients with BLISTER scores ≥6 (10.8%), delivering a significant reduction in infections (relative risk reduction, 30%; P=0.036) within the National Institute for Health and Care Excellence cost-utility thresholds (ICER, £18 446). CONCLUSIONS: The BLISTER score (https://qxmd.com/calculate/calculator_876/the-blister-score-for-cied-infection) was a valid predictor of cardiac implantable electronic device infection, and could facilitate cost-effective antimicrobial envelope allocation to high-risk patients.

Type: Article
Title: Blister Score: A Novel, Externally Validated Tool for Predicting Cardiac Implantable Electronic Device Infections, and Its Cost-Utility Implications for Antimicrobial Envelope Use
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1161/CIRCEP.123.012446
Publisher version: http://dx.doi.org/10.1161/circep.123.012446
Language: English
Additional information: © 2024 The Authors. Circulation: Arrhythmia and Electrophysiology is published on behalf of the American Heart Association, Inc., by Wolters Kluwer Health, Inc. This is an open access article under the terms of the Creative Commons Attribution Non-Commercial-NoDerivs License, which permits use, distribution, and reproduction in any medium, provided that the original work is properly cited, the use is noncommercial, and no modifications or adaptations are made.
Keywords: atrial fibrillation, cardiac resynchronization therapy, electronics, heart failure, quality of life
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Clinical Science
URI: https://discovery-pp.ucl.ac.uk/id/eprint/10188817
Downloads since deposit
532Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item