Knops, RE;
El-Chami, MF;
Marquie, C;
Nordbeck, P;
Quast, AFBE;
Tilz, RR;
Brouwer, TF;
... Smeding, L; + view all
(2024)
Predictive value of the PRAETORIAN score for defibrillation test success in patients with subcutaneous ICD: A subanalysis of the PRAETORIAN-DFT trial.
Heart Rhythm
10.1016/j.hrthm.2024.02.005.
(In press).
Preview |
PDF
1-s2.0-S1547527124001152-main.pdf - Published Version Download (1MB) | Preview |
Abstract
Background: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. Objective: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. Methods: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. Results: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13–279.95; P <.001). Conclusion: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.
Type: | Article |
---|---|
Title: | Predictive value of the PRAETORIAN score for defibrillation test success in patients with subcutaneous ICD: A subanalysis of the PRAETORIAN-DFT trial |
Location: | United States |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1016/j.hrthm.2024.02.005 |
Publisher version: | http://dx.doi.org/10.1016/j.hrthm.2024.02.005 |
Language: | English |
Additional information: | © 2024 Heart Rhythm Society. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
Keywords: | Defibrillation testing, PRAETORIAN score, Subcutaneous ICD, Transvenous ICD, Ventricular arrhythmia |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Clinical Science |
URI: | https://discovery-pp.ucl.ac.uk/id/eprint/10190518 |
Archive Staff Only
View Item |