UCL Discovery Stage
UCL home » Library Services » Electronic resources » UCL Discovery Stage

Label-free Electrochemical Immunosensor for Monitoring Kidney Transplant Rejection with Electroactive Antibiofouling Hydrogel

Gupta, Rohit; Salaris, Nikolaos; Kalkal, Ashish; Mandal, Priya; Balabani, Stavroula; Motallebzadeh, Reza; Tiwari, Manish K; (2024) Label-free Electrochemical Immunosensor for Monitoring Kidney Transplant Rejection with Electroactive Antibiofouling Hydrogel. IEEE Sensors Letters 10.1109/lsens.2024.3399604. (In press). Green open access

[thumbnail of Motallebzadeh_Label-free Electrochemical Immunosensor for Monitoring Kidney Transplant Rejection with Electroactive Antibiofouling Hydrogel_AAM.pdf]
Preview
Text
Motallebzadeh_Label-free Electrochemical Immunosensor for Monitoring Kidney Transplant Rejection with Electroactive Antibiofouling Hydrogel_AAM.pdf

Download (494kB) | Preview

Abstract

Diagnosing acute rejection of kidney transplant remains challenging as standard practice relies on monitoring serum creatinine levels and performing biopsies. The former lacks sensitivity, while the latter is invasive. Monitoring Chemokine IP-10 (or CXCL10) in patient samples has shown promising results in addressing these bottlenecks but is measured with expensive and time-consuming protocols such as enzyme-linked immunosorbent assay (ELISA). This does not allow for an individualized approach. The present work describes the development of a novel screen-printed electrode-based electrochemical biosensor for IP-10 detection using an electroactive anti-biofouling hydrogel. The electrode coating is based on glutaraldehyde (GA)-crosslinked 3D nanostructured bovine serum albumin (BSA) hydrogel, whose pores are filled with a highly conductive Ti3C2Tx MXene. The formulation is water-based and avoids the use of toxic solvents. The crosslinking mechanism, anti-biofouling characteristics, and electroactivity were characterized by UV-VIS spectroscopy, contact angle measurement, and cyclic voltammetry tests, respectively. The antibody-functionalized MXene/BSA/GA nanocomposite-based sensor allows the detection of IP-10 spiked in human serum by achieving an LOD of 3.3 pg/ml with a linear range across 1-200 pg/ml and a response time of 30 min. The study paves the way toward developing a highly specific multiplexed chemokine profiling platform for point-of-care diagnostics applications to monitor kidney transplant rejection.

Type: Article
Title: Label-free Electrochemical Immunosensor for Monitoring Kidney Transplant Rejection with Electroactive Antibiofouling Hydrogel
Open access status: An open access version is available from UCL Discovery
DOI: 10.1109/lsens.2024.3399604
Publisher version: http://dx.doi.org/10.1109/lsens.2024.3399604
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher's terms and conditions.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Mechanical Engineering
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci > Department of Surgical Biotechnology
URI: https://discovery-pp.ucl.ac.uk/id/eprint/10192283
Downloads since deposit
1,900Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item