Design and characterisation of multi-cavity, fluidic haptic feedback system for mechano-tactile feedback

Shi, G; Shi, Jialei; Shariati, A; Motaghedolhagh, K; Homer-Vanniasinkam, S; Wurdemann, Helge; (2024) Design and characterisation of multi-cavity, fluidic haptic feedback system for mechano-tactile feedback. IEEE Transactions on Haptics (In press). Green open access

[thumbnail of Shi et al. Design and characterisation of multi-cavity, fluidic haptic feedback system.pdf]
Preview
PDF
Shi et al. Design and characterisation of multi-cavity, fluidic haptic feedback system.pdf - Accepted Version

Download (19MB) | Preview

Abstract

Numerous studies have indicated that the use of a closed-loop haptic feedback system, which offers various mechano-tactile stimuli patterns with different actuation methods, can improve the performance and grasp control of prosthetic hands. Purely mechanical-driven feedback approaches for various mechano-tactile stimuli patterns, however, have not been explored. In this paper, a multi-cavity fluidic haptic feedback system is introduced with details of design, fabrication, and validation. The multi-cavity haptic feedback system can detect the physical touch with direction at the fingertip sensor. The direction of the force is reflected in the form of pressure deviation in the multi-cavity fingertip sensor. The feedback actuator generates various mechano-tactile stimuli patterns according to the pressure deviation from the fingertip sensor. Hence, users can identify the force with direction according to the stimuli patterns. The haptic feedback system is validated through two experiments. The initial experiment characterises the system and establishes the relationship between the fingertip sensor and feedback actuator. The subsequent experiment, a human interaction test, confirms the system’s capability to detect force with directions and generate corresponding tactile stimuli in the feedback actuator. The outcomes corroborate the idea that participants are generally capable of discerning changes in angle.

Type: Article
Title: Design and characterisation of multi-cavity, fluidic haptic feedback system for mechano-tactile feedback
Open access status: An open access version is available from UCL Discovery
Publisher version: https://ieeexplore.ieee.org/xpl/RecentIssue.jsp?pu...
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher's terms and conditions.
Keywords: Haptic Feedback System, Mechanotactile Stimulation, Soft Robotics, Upper-limb Prosthetics.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Mechanical Engineering
URI: https://discovery-pp.ucl.ac.uk/id/eprint/10196449
Downloads since deposit
3,348Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item