UCL Discovery Stage
UCL home » Library Services » Electronic resources » UCL Discovery Stage

Fracture Toughness of Short Fibre-Reinforced Composites—In Vitro Study

Kamourieh, Noor; Faigenblum, Maurice; Blizard, Robert; Leung, Albert; Fine, Peter; (2024) Fracture Toughness of Short Fibre-Reinforced Composites—In Vitro Study. Materials , 17 (21) , Article 5368. 10.3390/ma17215368. Green open access

[thumbnail of Fine_materials-17-05368-v2.pdf]
Preview
Text
Fine_materials-17-05368-v2.pdf

Download (8MB) | Preview

Abstract

The development of dental materials needs to be supported with sound evidence. This in vitro study aimed to measure the fracture toughness of a short fibre-reinforced composite (sFRC), at differing thicknesses. In this study, 2 mm, 3 mm and 4 mm depths of sFRC were prepared. Using ISO4049, each preparation was tested to failure. A total of 60 samples were tested: 10 samples for each combination of sFRC and depth. Fractured samples were viewed, and outcomes were analysed. EXF showed greater toughness than EXP, with a mean of 2.49 (95%CI: 2.25, 2.73) MPa.m1/2 compared to a mean of 2.13 (95%CI: 1.95, 2.31) MPa.m1/2, (F(1,54) = 21.28; p < 0.001). This difference was particularly pronounced at 2 mm depths where the mean (95%CI) values were 2.72 (2.49, 2.95) for EXF and 1.90 (1.78, 2.02) for EXP (Interaction F(2,54) = 7.93; p < 0.001). Both materials performed similarly at the depths of 3 mm and 4 mm. The results for both materials were within the accepted fracture toughness values of dentine of 1.79–3.08 MPa.m1/2. Analysis showed crack deflection and bridging fibre behaviour. The optimal thickness at the cavity base for EXF was 2 mm and for EXP 4 mm. Crack deflection and bridging behaviour indicated that restorations incorporating sFRCs are not prone to catastrophic failure and confirmed that sFRCs have similar fracture toughness to dentine. sFRCs could be a suitable biomimetic material to replace dentine.

Type: Article
Title: Fracture Toughness of Short Fibre-Reinforced Composites—In Vitro Study
Open access status: An open access version is available from UCL Discovery
DOI: 10.3390/ma17215368
Publisher version: http://dx.doi.org/10.3390/ma17215368
Language: English
Additional information: © 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Keywords: short fibre-reinforced composite; fracture toughness; everX Posterior; everX Flow; glass fibres; biomimetics
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Eastman Dental Institute
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Eastman Dental Institute > EDI Continuing Professional Develop.
URI: https://discovery-pp.ucl.ac.uk/id/eprint/10199715
Downloads since deposit
48Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item