UCL Discovery Stage
UCL home » Library Services » Electronic resources » UCL Discovery Stage

Seismic retrofitting of masonry infilled RC buildings in low-to moderate-seismic regions: case study of typical Sri Lankan school buildings

Sathurshan, M; Thamboo, J; Rossetto, T; Wijesundara, K; Mallikarachchi, C; Cels, J; Baiguera, M; ... Dias, P; + view all (2024) Seismic retrofitting of masonry infilled RC buildings in low-to moderate-seismic regions: case study of typical Sri Lankan school buildings. Bulletin of Earthquake Engineering , 22 (13) pp. 6441-6471. 10.1007/s10518-024-02010-y.

[thumbnail of Rossetto_BEEE-D-23-00836_revised manuscript_19072024_clear version.pdf] Text
Rossetto_BEEE-D-23-00836_revised manuscript_19072024_clear version.pdf
Access restricted to UCL open access staff until 3 September 2025.

Download (3MB)

Abstract

Seismic retrofitting solutions for reinforced concrete (RC) school building types in high-seismic regions are extensively reported in the state-of-the-art. Conversely, limited studies have focused on the extent of retrofitting needed for RC school buildings in low- to moderate-seismic regions. To explore this aspect, seismic retrofitting options for RC school buildings in Sri Lanka are investigated. Three retrofitting options are examined: (1) adding/altering masonry infill walls (MI walls) to reduce irregularity in buildings, (2) RC jacketing of columns and (3) a combination of adding/altering MI walls and RC jacketing. These retrofit options are applied to a common typology of Sri Lankan MI-RC school buildings, considering two and three storey height variations. A simplified numerical modelling approach that accounts for the contribution of MIs, the shear failure of RC column and torsional effects is adopted to analyse the performance of the school buildings with and without retrofit. Based on the analyses, three damage states are defined: damage limitation (DL), significant damage (SD) and near collapse (NC). Finally, a multi-criteria decision making (MCDM) method is used to determine the optimal retrofitting option for the considered school building typology, considering engineering and economic parameters. The optimal retrofit solution for the three-storey MI-RC school building is found to be jacketing of ground floor columns. Conversely, for the two-storey MI-RC school building, alteration of infill walls (MI walls) is deemed optimal. Finally, a sensitivity analysis is carried out on the MCDM method.

Type: Article
Title: Seismic retrofitting of masonry infilled RC buildings in low-to moderate-seismic regions: case study of typical Sri Lankan school buildings
DOI: 10.1007/s10518-024-02010-y
Publisher version: https://doi.org/10.1007/s10518-024-02010-y
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Reinforced concrete buildings, Retrofitting, Seismic vulnerability, Masonry infills, RC jacketing, Shear failure, Multi-criteria decision making (MCDM)
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Civil, Environ and Geomatic Eng
URI: https://discovery-pp.ucl.ac.uk/id/eprint/10201192
Downloads since deposit
11Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item