UCL Discovery Stage
UCL home » Library Services » Electronic resources » UCL Discovery Stage

Comparison of baseline clinical characteristics and patterns of visual field defects between high-tension and normal-tension glaucoma

Chen, Zidong; Yang, Wenxin; Yang, Yangfan; Jiang, Yuzhen; Zhang, Yuning; Zhang, Xinyi; Luo, Chongxuan; ... LiGHT China Trial Study Group; + view all (2024) Comparison of baseline clinical characteristics and patterns of visual field defects between high-tension and normal-tension glaucoma. British Journal of Ophthalmology 10.1136/bjo-2023-324852. (In press). Green open access

[thumbnail of Gazzard_Baseline Clinical Characteristics and Patterns of Visual Field Defect in Primary Open-Angle Glaucoma Comparison Between High-Tension and Normal-Tension Gl.pdf]
Preview
Text
Gazzard_Baseline Clinical Characteristics and Patterns of Visual Field Defect in Primary Open-Angle Glaucoma Comparison Between High-Tension and Normal-Tension Gl.pdf

Download (692kB) | Preview

Abstract

Aims: To compare the baseline clinical characteristics and patterns of visual field defects between high-tension glaucoma (HTG) and normal-tension glaucoma (NTG) in the Laser in Glaucoma and Ocular Hypertension (LiGHT) China subjects. // Methods: All patients (n=622) were recruited at Zhongshan Ophthalmic Center from 2015 to 2019. 1105 open-angle glaucoma eyes of 622 patients were classified as NTG (n=559) and HTG eyes (n=546) according to the baseline intraocular pressure (IOP) of 21 mm Hg. The mean deviation (MD), regional MD of the Glaucoma Hemifield Test regions and regional difference values were calculated. Daytime phasing IOP was recorded at 8:00, 10:00, 11:30, 14:30 and 17:00 hour. Multiple regression analyses were conducted for each regional difference. // Results: Patients with NTG were older, more likely to be female, hypertensive and suffer ischaemic heart disease than patients with HTG (p<0.05 for all comparisons). HTG showed higher mean daytime phasing IOP and higher daytime fluctuations than NTG (p<0.001 for all comparisons). HTG and NTG showed similar MD overall (p=0.665). NTG showed significantly greater hemifield asymmetry than HTG. The two arcuate regional differences in NTG were significantly associated with daytime IOP fluctuations (p<0.01 in both regions). // Conclusions: In the LiGHT China trial, NTG and HTG showed similar visual field defects severity at enrolment. However, NTG showed more severe hemifield asymmetry compared with HTG, and higher short-time IOP fluctuations might exacerbate this asymmetry in NTG.

Type: Article
Title: Comparison of baseline clinical characteristics and patterns of visual field defects between high-tension and normal-tension glaucoma
Location: England
Open access status: An open access version is available from UCL Discovery
DOI: 10.1136/bjo-2023-324852
Publisher version: https://doi.org/10.1136/bjo-2023-324852
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > Institute of Ophthalmology
URI: https://discovery-pp.ucl.ac.uk/id/eprint/10202831
Downloads since deposit
72Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item