Evaluation of motion-correction methods for dual-gated cardiac positron emission tomography/computed tomography imaging.
Nuclear Medicine Communications
, 37
(9)
pp. 956-968.
10.1097/MNM.0000000000000539.
Preview |
Text
thielemans_CT-based motion correction_03032016_NMC.pdf Download (1MB) | Preview |
Abstract
BACKGROUND: Dual gating is a method of dividing the data of a cardiac PET scan into smaller bins according to the respiratory motion and the ECG of the patient. It reduces the undesirable motion artefacts in images, but produces several images for interpretation and decreases the quality of single images. By using motion-correction techniques, the motion artefacts in the dual-gated images can be corrected and the images can be combined into a single motion-free image with good statistics. AIM: The aim of the present study is to develop and evaluate motion-correction methods for cardiac PET studies. We have developed and compared two different methods: computed tomography (CT)/PET-based and CT-only methods. METHODS: The methods were implemented and tested with a cardiac phantom and three patient datasets. In both methods, anatomical information of CT images is used to create models for the cardiac motion. RESULTS: In the patient study, the CT-only method reduced motion (measured as the centre of mass of the myocardium) on average 43%, increased the contrast-to-noise ratio on average 6.0% and reduced the target size on average 10%. Slightly better figures (51, 6.9 and 28%) were obtained with the CT/PET-based method. Even better results were obtained in the phantom study for both the CT-only method (57, 68 and 43%) and the CT/PET-based method (61, 74 and 52%). CONCLUSION: We conclude that using anatomical information of CT for motion correction of cardiac PET images, both respiratory and pulsatile motions can be corrected with good accuracy.
Type: | Article |
---|---|
Title: | Evaluation of motion-correction methods for dual-gated cardiac positron emission tomography/computed tomography imaging |
Location: | England |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1097/MNM.0000000000000539 |
Publisher version: | http://doi.org/10.1097/MNM.0000000000000539 |
Language: | English |
Additional information: | Copyright © 2016 Wolters Kluwer Health, Inc. All rights reserved. This is a non-final version of an article published in final form in Klén, R; Noponen, T; Koikkalainen, J; Lötjönen, J; Thielemans, K; Hoppela, E; Sipilä, H; (2016) Evaluation of motion-correction methods for dual-gated cardiac positron emission tomography/computed tomography imaging. Nuclear Medicine Communications , 37 (9) pp. 956-968. 10.1097/MNM.0000000000000539. |
Keywords: | Cardiac positron emission tomography imaging, dual gating, motion correction |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine > Department of Imaging |