Pedersen, SS;
Mastenbroek, MH;
Carter, N;
Barr, C;
Neuzil, P;
Scholten, M;
Lambiase, PD;
... Theuns, DAMJ; + view all
(2016)
A Comparison of the Quality of Life of Patients With an Entirely Subcutaneous Implantable Defibrillator System Versus a Transvenous System (from the EFFORTLESS S-ICD Quality of Life Substudy).
The American Journal of Cardiology
, 118
(4)
pp. 520-526.
10.1016/j.amjcard.2016.05.047.
Preview |
Text
Lambiase_a comparison_from EFFORTLESS S-ICD_.pdf - Accepted Version Download (623kB) | Preview |
Abstract
The first clinical results from the Evaluation of Factors Impacting Clinical Outcome and Cost Effectiveness of the subcutaneous implantable cardioverter defibrillator (EFFORTLESS S-ICD) Registry on the entirely S-ICD system are promising, but the impact of the S-ICD system on patients' quality of life (QoL) is not known. We evaluated the QoL of patients with an S-ICD against an unrelated cohort with a transvenous (TV)-ICD system during 6 months of follow-up. Consecutively implanted patients with an S-ICD system were matched with patients with a TV-ICD system on a priori selected variables including baseline QoL. QoL was measured with the Short-Form Health Survey at baseline, 3, and 6 months after implant and compared using multivariable modeling with repeated measures. Patients with an S-ICD (n = 167) versus a TV-ICD system (n = 167) did not differ significantly on physical (p = 0.8157) and mental QoL scores (p = 0.9080) across baseline, 3, and 6 months after implantation in adjusted analyses. The evolution in physical (p = 0.0503) and mental scores (p = 0.3772) during follow-up was similar for both cohorts, as indicated by the nonsignificant interaction effect for ICD system by time. Both patients with an S-ICD system and a TV-ICD system experienced significant improvements in physical and mental QoL between time of implant and 3 months (both p's <0.0001) and between time of implant and 6 months (both p's <0.0001) but not between 3 and 6 months (both p's >0.05). In conclusion, these first results show that the QoL of patients with an S-ICD versus TV-ICD system is similar and that patients with either system experience improvements in QoL on the short term.
Type: | Article |
---|---|
Title: | A Comparison of the Quality of Life of Patients With an Entirely Subcutaneous Implantable Defibrillator System Versus a Transvenous System (from the EFFORTLESS S-ICD Quality of Life Substudy) |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1016/j.amjcard.2016.05.047 |
Publisher version: | http://doi.org/10.1016/j.amjcard.2016.05.047 |
Language: | English |
Additional information: | This version is the author accepted manuscript / version of record [delete as appropriate]. For information on re-use, please refer to the publisher’s terms and conditions. |
Keywords: | Science & Technology, Life Sciences & Biomedicine, Cardiac & Cardiovascular Systems, Cardiovascular System & Cardiology, Cardioverter-defibrillator, D Personality, Ventricular-arrhythmias, Negative Affectivity, Social Inhibition, Heart-failure, Health-status, Outcomes, Anxiety, Depression |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Clinical Science |
URI: | https://discovery-pp.ucl.ac.uk/id/eprint/1502572 |
Archive Staff Only