Zane, S;
Winter, B;
Theobalds, C;
Theodorou, T;
Pinchera, M;
Muleri, F;
Spada, F;
... Weisskopf, M; + view all
(2016)
The on-board calibration system of the X-ray Imaging Polarimetry Explorer (XIPE).
Proceedings of SPIE - The International Society for Optical Engineering
, 9905
, Article 99054H. 10.1117/12.2233448.
Preview |
Text
Zane_99054H.pdf Download (1MB) | Preview |
Abstract
The calibration system for XIPE is aimed at providing a way to check and correct possible variations of performance of the Gas Pixel Detector during the three years of operation in orbit (plus two years of possible extended operation), while facilitating the observation of the celestial sources. This will be performed by using a filter wheel with a large heritage having a set of positions for the calibration and the observation systems. In particular, it will allow for correcting possible gain variation, for measuring the modulation factor using a polarized source, for removing non interesting bright sources in the field of view and for observing very bright celestial sources. The on-board calibration system is composed of three filter wheels, one for each detector and it is expected to operate for a small number of times during the year. Moreover, since it operates once at a time, within the observation mode, it allows for simultaneous calibration and acquisition from celestial sources on different detectors. In this paper we present the scope and the requirements of the on-board calibration system, its design, and a description of its possible use in space.
Type: | Article |
---|---|
Title: | The on-board calibration system of the X-ray Imaging Polarimetry Explorer (XIPE) |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1117/12.2233448 |
Publisher version: | http://doi.org/10.1117/12.2233448 |
Language: | English |
Additional information: | © 2016 SPIE. Copyright 2016 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. |
Keywords: | X-ray polarimetry |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Maths and Physical Sciences UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Maths and Physical Sciences > Dept of Space and Climate Physics |
URI: | https://discovery-pp.ucl.ac.uk/id/eprint/1508124 |
Archive Staff Only
View Item |