UCL Discovery Stage
UCL home » Library Services » Electronic resources » UCL Discovery Stage

Dual-site right ventricular pacing in patients undergoing cardiac resynchronization therapy: Results of a multicenter propensity-matched analysis

Providencia, R; Barra, S; Papageorgiou, N; Ioannou, A; Rogers, D; Wongwarawipat, T; Falconer, D; ... Chow, AW; + view all (2017) Dual-site right ventricular pacing in patients undergoing cardiac resynchronization therapy: Results of a multicenter propensity-matched analysis. Pacing and Clinical Electrophysiology , 40 (10) pp. 1113-1120. 10.1111/pace.13145. Green open access

[thumbnail of Lambiase_dual-site right ventricular pacing_.pdf]
Preview
Text
Lambiase_dual-site right ventricular pacing_.pdf - Accepted Version

Download (367kB) | Preview

Abstract

BACKGROUND: Dual-site right ventricular pacing (Dual RV) has been proposed as an alternative for patients with heart failure undergoing cardiac resynchronization therapy (CRT) with a failure to deliver a coronary sinus (CS) lead. Only short-term hemodynamic and echocardiographic results of Dual RV are available. We aimed to assess the long-term results of Dual RV and its impact on survival. METHODS: Multicenter retrospective assessment of all CRT implants during a 12-year period. Patients with failed CS lead implantation, treated with Dual RV, were followed and assessed for the primary endpoint of all-cause mortality and/or heart transplant. A control group was obtained from contemporary patients using propensity matching for all available baseline variables. RESULTS: Ninety-three patients were implanted with Dual RV devices and compared with 93 matched controls. During a median of 1,273 days (interquartile range 557-2,218), intention-to-treat analysis showed that all-cause mortality and/or heart transplant was higher in the Dual RV group (adjusted hazard ratio [HR] = 1.66, 95% confidence interval [CI] 1.12-2.47, P = 0.012). As-treated analysis yielded similar results (HR = 1.97, 95% CI 1.31-2.96, P = 0.001). Cardiac device-related infections occurred seven times more frequently in the Dual RV site group (HR = 7.60, 95% CI 1.51-38.33, P = 0.014). Among Dual RV nonresponders, four had their apical leads switched off, five required an epicardial LV lead insertion, a transseptal LV lead was implanted in two, and in nine patients, after reviewing the CS venogram, a new CS lead insertion was successfully attempted. CONCLUSION: Dual RV pacing is associated with worse clinical outcomes and higher complication rates than conventional CRT.

Type: Article
Title: Dual-site right ventricular pacing in patients undergoing cardiac resynchronization therapy: Results of a multicenter propensity-matched analysis
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1111/pace.13145
Publisher version: https://doi.org/10.1111/pace.13145
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Cardiac resynchronization therapy, electrical dyssynchrony, endocardial pacing, heart failure
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Clinical Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Health Informatics
URI: https://discovery-pp.ucl.ac.uk/id/eprint/1571969
Downloads since deposit
9,196Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item