UCL Discovery Stage
UCL home » Library Services » Electronic resources » UCL Discovery Stage

Online fluorescence spectroscopy for the real-time evaluation of the microbial quality of drinking water

Sorensen, JPR; Vivanco, A; Ascott, MJ; Gooddy, DC; Lapworth, DJ; Read, DS; Rushworth, CM; ... Taylor, RG; + view all (2018) Online fluorescence spectroscopy for the real-time evaluation of the microbial quality of drinking water. Water Research , 137 pp. 301-309. 10.1016/j.watres.2018.03.001. Green open access

[thumbnail of Taylor_Online fluorescence spectroscopy for the real-time evaluation of the microbial quality of drinking water_VoR.pdf]
Preview
Text
Taylor_Online fluorescence spectroscopy for the real-time evaluation of the microbial quality of drinking water_VoR.pdf - Published Version

Download (1MB) | Preview

Abstract

We assessed the utility of online fluorescence spectroscopy for the real-time evaluation of the microbial quality of untreated drinking water. Online fluorimeters were installed on the raw water intake at four groundwater-derived UK public water supplies alongside existing turbidity sensors that are used to forewarn of the presence of microbial contamination in the water industry. The fluorimeters targeted fluorescent dissolved organic matter (DOM) peaks at excitation/emission wavelengths of 280/365 nm (tryptophan-like fluorescence, TLF) and 280/450 nm (humic-like fluorescence, HLF). Discrete samples were collected for Escherichia coli, total bacterial cell counts by flow cytometry, and laboratory-based fluorescence and absorbance. Both TLF and HLF were strongly correlated with E. coli (ρ = 0.71–0.77) and total bacterial cell concentrations (ρ = 0.73–0.76), whereas the correlations between turbidity and E. coli (ρ = 0.48) and total bacterial cell counts (ρ = 0.40) were much weaker. No clear TLF peak was observed at the sites and all apparent TLF was considered to be optical bleed-through from the neighbouring HLF peak. Therefore, a HLF fluorimeter alone would be sufficient to evaluate the microbial water quality at these sources. Fluorescent DOM was also influenced by site operations such as pump start-up and the precipitation of cations on the sensor windows. Online fluorescent DOM sensors are a better indicator of the microbial quality of untreated drinking water than turbidity and they have wide-ranging potential applications within the water industry.

Type: Article
Title: Online fluorescence spectroscopy for the real-time evaluation of the microbial quality of drinking water
Open access status: An open access version is available from UCL Discovery
DOI: 10.1016/j.watres.2018.03.001
Publisher version: https://doi.org/10.1016/j.watres.2018.03.001
Language: English
Additional information: © 2018 British Geological Survey, a component institute of NERC - 'BGS © NERC 2018'. Published by Elsevier Ltd. This is an open access article under the CC BY license (https://creativecommons.org/licenses/by/4.0/).
Keywords: Online fluorescence spectroscopy, Turbidity, Flow cytometry, Faecal contamination, Drinking water, Bacteria enumeration
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL SLASH
UCL > Provost and Vice Provost Offices > UCL SLASH > Faculty of S&HS
UCL > Provost and Vice Provost Offices > UCL SLASH > Faculty of S&HS > Dept of Geography
URI: https://discovery-pp.ucl.ac.uk/id/eprint/10049729
Downloads since deposit
14,668Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item